Skip to main content

Otowave 302 Plus Tympanometer with Probe tone 226 / 1000Hz

Amplivox Otowave

$4,325.00
Free Shipping
(No reviews yet) Write a Review
Availability:
Usually ships in 24 hours
Shipping:
Free Shipping
Adding to cart… The item has been added

Free Shipping within the Continental US

Amplivox Otowave 302+ Desktop Tympanometer with PC connectivity  8522198 (with printer)

Otowave 302 w/6 programmable profiles & 1000Hz probe-tone.

The Amplivox 302+ tympanometer with Probe tone impedance measurements at 226Hz and 1000Hz; focuses on supporting time management, whilst providing accurate middle ear measurements. It includes a customisable, six profile selection structure to save you time changing test settings. 

Three are default profiles for adult, child and neonate, and a further three are blank profiles to personally adjust.

 

Features

  • Large digital display for fast, accurate impedance measurements 
  • 226Hz probe tone and 1kHz probe tone with admittance, susceptance and conductance measurements (YBG)
  • Measurements shown in real time
  • Ipsilateral and contralateral reflex frequencies (0.5, 1, 2 & 4kHz)
  • Enhanced mode reflex test
  • Auto pass/refer evaluation
  • Six fully customisable test protocols
  • User-selectable measurement speeds
  • Internal memory, connection to thermal printer and/or PC.

Printer included.

 

The Otowave 302+ features extended functions including user defined:
Probe tone impedance measurements at 226Hz and 1000Hz (scalar,
vector and component measurements; admittance (Y),
susceptance (B), conductance (G))
Range of ipsilateral and contralateral reflex test measurements at
500Hz, 1kHz, 2kHz and 4kHz
Six user configurable test profiles designed to standardise test
sessions and reduce test times. This includes three profiles for adult,
child and neonate, plus three customisable profiles based upon
your needs.

 

Settings

Three pre-set profiles and three customisable profiles, the 302+ can easily be adjusted to suit your requirements.

This includes adjustable test settings for the following:

  • Probe tone (226 / 1000Hz)
  • Sweep speeds
  • Ipsilateral reflex frequencies
  • Contralateral reflex frequencies
  • Fixed test level or threshold test
  • Pass/Refer criteria

Test settings can easily be changed depending on your preference or test subject in question. The Otowave 302 offers you to easily define the following test settings in no time.

  

The Amplivox Otowave 302 Tympanometer intuitive to use with clear on-screen information, which can be easily seen from a wide range of viewing positions. Results can be saved within internal memory with a patient identifier, printed via the optional portable thermal printer, transferred to a PC using the supplied Amplivox Tymp View application for paper print and electronic document requirements, transferred to the NOAH database using the supplied Amplivox NOAH Impedance module.

All tympanometers include free to use ampli Suite. This very easy to use software allows you to easily transfer results, analyse, add patient data, categorise, print and store.

Amplivox also includes the NOAH connection module and many other Electronic Medical Record (EMR) providers have integrated this product to their system for easy data management.

  

Tympanometry measurements
Probe tone level & accuracy: 226Hz +/-2%; 85dBSPL +/-2dB
1000Hz +/- 2%; 79dBSPL +/-2dB
(302+) over ear canal volume range
Pressure range & accuracy: +200daPa to -400daPa +/- 10daPa or
+/-10% (whichever is larger) over range
0.1ml to 5ml
Direction of sweep: Positive to negative pressure
Volumetric range & accuracy: 226Hz: 0.2ml to 5ml
1000Hz: 0.1ml to 5ml
+/-0.1ml or +/-5% (whichever is larger)
Analysis performed: Admittance peak level in ml (226Hz)
or mƱ (1000Hz) & pressure at peak;
Gradient in daPa (for 226Hz);
Ear canal volume (ECV)
Measurement sweep speeds: Selectable: 100, 200 or 300 daPa/sec.

Reflex measurements
Reflex type: Ipsilateral, contralateral or both
Reflex frequencies: Ipsilateral and contralateral:
User-configurable.
Selectable from: 500Hz, 1kHz, 2kHz
& 4kHz (+/-2%)
Reflex levels (max levels): Ipsilateral: 70dBHL to 100dBHL (+/-3dB)
Contralateral: 70dBHL to110dBHL
(+/-3dB)
95 / 90 / 85dbHL max, with
5dB steps (Otowave 302+)
Reflex detection threshold: 0.01ml to 0.5ml +/-0.01ml
(configurable in 0.01ml steps)
Analysis performed: Reflex maximum amplitude and pass/
fail at each test level
EMC: IEC 60601-1-2
Audiometric: IEC 60645-1
CE Mark: Complies to EU Medical Device Directive

Standard Equipment 

  • Eartip selection box
  • Contralateral transducer
  • 4x test cavities
  • Spare probe tips and gaskets
  • Carrying case
  • Power Supply with country adaptors
  • USB cable (PC connection)
  • ampliSuite PC software (stand-alone)
  • Noah impedance module
  • Printer Included.

 

Otowave 302+ tympanometer No Printer Part no. 8522197

available per request.

 

Accessories

Ear Tips

Probe Tips

 

 

 

 

 

New 3 years Warranty
*FREE ground shipping within the Continental United States.:
*FREE ground shipping within the Continental United States.
3 Years Warranty:
3 Years Warranty

Videos Hide Videos Show Videos

Click for the BBB Business Review of this Medical Equipment & Supplies in Miami FL